
Figure-8 Aerial Cable — GYFTC8A
Two to twenty-four loose tubes stranded around an FRP member, aluminium tape and black HDPE sheath, with an integrated galvanised messenger for self-supporting aerial installation.
Twenty product families have downloadable datasheets; the remainder are configured per project.
Five installation methods covered: aerial, duct, direct-buried, air-blown and drop, from 12 to 288 fibres, G.652D as standard and G.657A1 for tight bends.

Two to twenty-four loose tubes stranded around an FRP member, aluminium tape and black HDPE sheath, with an integrated galvanised messenger for self-supporting aerial installation.

Higher fibre count up to 216, for longer spans and higher-density aerial distribution.

Aramid yarn strength members and an all-dielectric construction allow installation on live power lines; the AT sheath provides tracking resistance.

Small diameter and low-friction sheath for microduct installation, reducing excavation work.

Corrugated steel tape between two sheaths, for routes with rodents, rock or heavy traffic.

Standard loose-tube duct cable with water-blocking yarn and HDPE sheath, 24 to 216 cores.

Bow-type construction with FRP strength members, 1 to 12 fibres and LSZH jacket, for wall fixing and conduit installation.

Ribbon fibres with steel tape and wire armouring, for direct burial and high-density splicing.

12-fibre central tube with an integrated messenger, for short aerial spans.
Closures from 12 to 288 fibres, terminals, splitters, patch cords and span fittings, with mechanical sealing for repeated on-site re-entry.

395 mm body with six 12-core splice trays and five cable ports.

Six 24-core trays with 12C drop grommets, so one closure handles both splicing and distribution.

Twelve 24-core trays, with a drop platform for up to 24 × 12C aerial cables.

Compact lightweight closure for aerial and duct splices.

Wall-mounted subscriber terminal with splice tray, adapter panel and pre-terminated pigtails.

Planar lightwave splitters from 1×2 to 1×32 in bare-fibre or cassette form, with consistent outputs.

Simplex, duplex and 12-colour pigtails, with armoured and waterproof pre-terminated options.

Single and duplex adapters in LC, SC and FC with UPC or APC polish, plus 1 to 20 dB attenuators.

Suspension, tension, anchor and wedge clamps, with steel band and buckles.
Rack units, ODF frames and patch cords for 19-inch racks. We do not provide room construction; only the optical layer inside the rack.

1U unit with LC adapters at the front, splice tray at the rear and rear cable entry; installs in either direction.

The same frame with SC adapters, for high-count single-mode termination.

Vertical distribution frame with adapter panels, splice trays and cord management space.
MPO trunks and pre-terminated modules are configured per project, with drawings for confirmation.
Datasheets follow the same structure in every family — construction, optical performance, tests, packing — for direct model comparison.
| Product | Model | Range | Datasheet |
|---|---|---|---|
| Figure-8 aerial cable | GYFTC8A | 12–288 F | |
| Figure-8 aerial cable | GYFTC8Y | 24–216 C | |
| Figure-8 semi-dry cable | GYFTC8Y G657A1 | 24 F | |
| ADSS cable | ADSS | 24–192 F | |
| ADSS cable | ADSS 48F | 48 F | |
| ADSS cable | ADSS 96F | 96 F | |
| Air-blown micro cable | GYCFHTY | 12–144 F | |
| Armoured outdoor cable | GYFTA | 12–288 C | |
| Duct cable | GYFTY | 24–216 C | |
| Drop cable | GJYXFCH-12B6a1 | 1–12 F | |
| Low-friction indoor cable | indoor | 1–24 F | |
| Central-tube aerial cable | GYBXTC8Y | 12 F | |
| Hybrid splice closure | ZYSC-GPJ09-5608 | 72 F | |
| Hybrid splice closure | ZY-GPJ09-5601 | 144 F | |
| Hybrid splice closure | HMO-GPJ09-6829 | 288 F | |
| LCP splice closure | HMO-GPJ09 | 144 F | |
| ATB fibre outlet box | ZY-MB-1B | 1–4 ports | |
| Mini PLC splitter | 1×N | 1×2–1×32 | |
| Rack FDU | LC | 19" | |
| Rack FDU | SC | 19" |
Fibre count, sheath colour, messenger size and packing are configured per order, with drawings confirmed before production.